Natural Gas Analyzers

Description

The RA-915 AMNG monitor is designed for continuous online monitoring of mercury concentration in natural gas.

Model

RA-915 AMNG

Applications

  • Mercury monitoring in natural gas
  • Feedback control of Mercury Removal Units (MRU)
  • Feed forward process control for MRU
  • Monitoring of MRU for petroleum refinery process gas
  • Design optimization of MRU
  • Gas analyzer buildings along pipelines and intersection points

Features

  • No chemicals, carrier gases, or zero gases
  • Zeeman Correction
  • Direct continuous measurements
  • Low detection limit and wide measurement range
  • Automatic zero drift correction
  • Automatic span drift correction
  • Long-term calibration stability
  • Low maintenance
  • Configuration options include:
    • 19" rack mounted enclosure
    • Purged enclosure suitable for Class 1 Division 2
    • Explosionproof enclosure suitable for Class 1 Division 1

Specifications

  • Principle of Operation: Atomic Absorption (AA)
  • Detection Limit: 1 - 5 ng/m3 (Treated gas)
  • Detection Limit: 0.5 - 1 μg/m3 (Raw Gas)
  • Power: 110/240 V, 50/60 Hz, 120 VA
  • Dimensions: varies based on configuration
  • Weight: varies based on configuration


 download brochure

In order to view/ read the Manual & the Brochure, you should have Adobe Reader Installed on your machine, in case you don't have it, download it here.

Related Products

RA-915+ Analyzer

RA-915+ Analyzer

More info
RA-915M Analyzer

RA-915M Analyzer

More info
Other Sorbent Traps

Other Sorbent Traps

More info

Description

The RP-91NG is an attachment for the RA-915+ or the RA-915M that allows for direct interference-free determination of mercury concentration in natural gas.

Model

RP-91NG Attachment (pictured with RA-915+ Analyzer)

Applications

  • Mercury Analysis in Natural Gas

Features

  • Zeeman Background Correction
  • Wide dynamic range of analysis
  • No sample preparation
  • Ease of operation
  • Portability
  • Robust and low maintenance
  • Direct determination of mercury without preliminary accumulation on a gold sorbent

Specifications

  • RP-91NG Principle of Operation: Atomic Absorption (AA)
  • RP-91NG Requirement: RA-915+ or RA-915M
  • RP-91NG Detection Limit: 0.01 μg/m3 (Range I)
  • RP-91NG Detection Limit: 0.50 μg/m3 (Range II)
  • RP-91NG Detection Range: 0.01 μg/m3 – 20 μg/m3 (Range I)
  • RP-91NG Detection Range: 0.50 μg/m3 – 2,000 μg/m3 (Range II)

 