Ohio Lumex Zeeman Mercury Analyzer








PRODUCTS Search
PRODUCTS | PARTS

Name Brief description of instruments
Mercury Analyzers
RA-915+ Mercury Analyzer
The Analyzer





Optional attachments:

RP-91 (for liquids)
RP91 Attachment

RP-91C (for solid samples)
RP91C Attachment
MORE INFO

APPLICATION SAMPLES

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS



RA-915+ Mercury Analyzer is a portable spectrometer designed for interference free analysis/monitoring of mercury content in ambient air, water, soil, natural and stack gases, chlorine alkali manufacturing, spill response, hazardous waste, foodstuff, biological materials.

US EPA validated high sensitivity and selectivity instrument that does not require gold amalgam pre-concentration and subsequent regeneration steps. This enables the user to conduct real time monitoring. Being combined with an RP-91 Cold Vapor accessory for water and RP-91C pyrolysis attachment for solid sample testing, the instrument is designed to determine mercury content in ambient air, water, soil, natural and stack gases, dental and medical testing and diagnostics, analysis of food and fish, etc. The detection limits being as low as 0.5 ng/m3 in air and 0.5 ng/l in water and 5 µg in soil.


   

Mercury Analyzer RA-915 Light
The Analyzer
MORE INFO


Mercury analyzer RA-915 LIGHT is a low cost analytical instrument for measuring mercury concentrations in air. It is intended for assessment of indoor/outdoor air quality in residential and industrial settings.


IRM-915 Transportable Mercury Stack Monitor
IRM915 Analyzer
MORE INFO

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS

IRM-915 Mercury Stack Monitor
is developed for temporary at-stack installation and Flue Gas testing for “Total” or “Elementary” mercury. Designed as an instrumental replacement for Ontario Hydro Method, this is a good tool for testing certification of permanent CEMM’s, and on-site performance evaluation of Mercury Control Technologies.

IRM-915 Mercury Stack Monitor has recently passed RATA (Relative Accuracy Test Audit). Result are available per request.
Appendix K Sorbent Trap Mercury Analyzer

NEW!
MORE INFO

APPLICATION SAMPLES

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS
Appendix K part 75 of the Clean Air Mercury Rule. US EPA validated thermal decomposition.

Appendix K Sorbent Trap Mercury Analyzer
is designed for field on-site or laboratory "Direct" testing of carbon tubes for Sorbent Trap Monitoring of Hg emissions from coal-fired power plants (formal method 324). Atomic Absorption technology is used for no sample preparation analysis. Analysis time is less than 2 minutes per sample. No liquid chemicals or gases required, no chemical waste is generated. In addition to Sorbent traps, analyzer could be used for "Direct" testing of ash, coal and "Ontario Hydro" method generated liquid samples.

Multi-point calibration protocol conforms to EPA Performance Based Criteria Method.

Thermal method using RP M-324 Mercury Analyzer and Sorbent Traps has passed RATA (Relative Accuracy Test Audit) at multiple power plant locations in the United States. Result are available per request.
RA-915 MiniCEM 2x

MORE INFO

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS

RA-915 MiniCEM 2x
is designed for field on-site testing of Flue Gas for Total mercury. Instrumental method intended as a replacement for Ontario Hydro Method. This is a good tool for point source stack testing and on-site performance evaluation of Mercury Control Technologies Detection for Total mercury 0.1µg/m3 - 200 µg/m3.


RA-915+ Mercury Analyzer with new pyrolyzer PYRO-915
MORE INFO

APPLICATION NOTES

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS
Direct mercury analyzer for EPA Method 7473 is the unique high sensitivity interference-free instrument for direct mercury determination in complex matrixes.
  • No sample preparation involved.
  • No compressed gases required.
  • No chemical waste generated.
  • Get accurate analytical results in less than a minute!
Method detection limit is 0.5 ug/kg.

View/Download Application notes in PDF format:

 

Mercury Analyzer RA-82
MORE INFO Mercury Analyzer RA-82 is employed for measuring weight concentration of mercury, which is implemented using a double-beam optical scheme with analytical and reference cells. To minimize the detection limit, mercury preconcentration on a gold trap is used.
Sorbent Traps
Laboratory Services

MORE INFO Ohio Lumex is a full staff laboratory capable of doing all of your sorbent trap analysis. Our laboratory is capable to analyze for mercury in sorbent traps as well as fly ash and coal. Our standard turnaround time is 1 week which means you will have results in less than 5 business days. We also can do RUSH analysis of 2 days, 24 hours, and SAME DAY analysis. We are known for our Exceptional QAQC, Inexpensive Pricing, and Guaranteed Confidentiality!
Method 30B Sorbent Trap
MORE INFO Method 30B Sorbent Traps are available for evaluations and RATA. These 6mm or 10mm extra durable 2-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling up to 2 liters per minute flow.
Method 30B Vapor-spiked Sorbent Trap
MORE INFO Method 30B Sorbent Traps at a variety of spike levels are available for evaluations and RATA. These 10mm extra durable 2-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling up to 2 liters per minute flow.

Custom spiking at any value you need is available.
Method 30B Sorbent Trap for Low Mass Emitter
MORE INFO Method 30B Sorbent Traps for Low Mass Emitters are available for evaluations, Low Mass Emitter Certifications, and RATA. These 10mm extra durable 2-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling 3-4 liters per minute flow.
Method 30B Vapor-spiked Sorbent Trap for Low Mass Emitter

MORE INFO
Method 30B Vapor-spiked Sorbent Traps for Low Mass Emitters are available for evaluations, Low Mass Emitter Certifications, and RATA. These 10mm extra durable 2-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling 3-4 liters per minute flow.

Custom spiking at any value you need is available. We can spike as low as 10ng when you are performing a RATA on a very low level site.
Appendix K RATA Vapor-spiked Sorbent Trap
MORE INFO Appendix K RATA Sorbent Traps at a variety of spike levels are available for evaluations and RATA. When performing a RATA on an Appendix K System, these are the traps used in the Appendix K System and are specially made to match the Method 30B traps perfectly. These 10mm extra durable 3-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling up to 2 liters per minute flow.

Custom spiking at any value you need is available.
Appendix K RATA Vapor-spiked Sorbent Trap for Low Mass Emitter

MORE INFO Appendix K RATA Sorbent Traps for low mass emitter at a variety of spike levels are available for evaluations and RATA. When performing a RATA on an Appendix K System, these are the traps used in the Appendix K System and are specially made to match the Method 30B traps perfectly. These 10mm extra durable 3-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling 3-4 liters per minute flow.

Custom spiking at any value you need is available. We can even spike as low as 10ng when you are performing a RATA on a very low level site.
Appendix K Long Term Testing Unspiked Sorbent Trap
MORE INFO
Appendix K Long Term Testing Unspiked Sorbent Traps are available for research purposes and to perform baseline evaluations. These 10mm extra durable 2 or 3-section sorbent traps are typically used for a 1-7+ day sampling and can be used when pulling up to 1 liter per minute flow.

Most customers will order these first to determine their spike level before they begin continuous testing.
Appendix K Long Term Testing Vapor-spiked Sorbent Trap
MORE INFO Appendix K Long Term Testing Vapor-Spiked Sorbent Traps at a variety of spike levels are available for Long Term and Continuous testing. These 10mm extra durable 3-section sorbent traps are typically used for a 1-7+ day sampling and can be used when pulling up to 1 liter per minute flow. They are all custom spiked for extra spike retention at any level the customer requires.
Customizations for the Sorbent Traps
MORE INFO All Ohio Lumex Sorbent Traps can be customized to fit the conditions of the source perfectly. We can add an Acid Gas Scrubber to any sorbent trap if the source has high Acid Gases, SO2, or SO3. We can create a special 3rd section to be extra spike retentive if the stack temperature is higher or acid gases are present. In these cases we can also create a special 1st section to be breakthrough resistant. For wet stacks we can build your trap to be moisture resistant in order to keep the sorbent completely dry during the testing. For clients who have high particulate in their stacks, to prevent traps from plugging up in a few days we can add a coiled particulate pre-filter inside of the traps in order to increase the surface area of the first plug.
Speciation Sorbent Trap
MORE INFO Speciation Sorbent Traps are available for evaluations, research, comparison with CEMMs or Ontario Hydro, and Sorbent Injection Efficiency Studies. These 10mm, extra long, and extra durable sorbent traps come with 2 types of sorbent. One sorbent collects only oxidized mercury while the other collects the elemental mercury. Moisture resistance and acid gas scrubbers come standard on these traps in order to prevent interference with the oxidized mercury.
Mercury Filters
Mercury Vapor Filter Scrubber
MORE INFO Mercury Vapor Filter Scrubber is designed for cleaning air from vapors of elementary mercury in breezing zone, for spill clean up, dental offices, manufacturing facilities, room decontamination, medical offices, schools, etc.



* 3 models available

IR Spectrometry
InfraLUM FT-02
MORE INFO

APPLICATION SAMPLES

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS
InfraLUM FT-02 FTIR Spectrometer contains, as a basic unit, a state-of-the-art robust vibration- and misalignment-proof Double-Cat-Eye interferometer of a proprietary design. The InfraLum-02 covers the spectral range of 350-7500 cm-1 and provides the photometric accuracy of 0.1%. The instrument is designed for identification of unknown substances, quantitative analysis of solutions and mixes, detection of impurities in atmospheric air and gases, and other similar analyses. The large sample compartment can accommodate all conventional and non-standard large cells and accessories. The use of the dedicated user-friendly SpectraLum control, data acquisition and processing software package, and calibration and reference databases allows even an unskilled operator to operate the instrument.
Automatic Analyzers
AKMC
 MORE INFO

APPLICATION SAMPLES

PERFORMANCE CHARACTERISTICS AND SPECIFICATIONS
AKMC-1 water hardness monitor is designed for stand-alone unattended continuous monitoring. The principle of operation of this instrument is based on potentiometric determination of the total content of calcium and magnesium ions (water hardness) in any natural or industrial water samples. The device may be used for monitoring at water preparation facilities and for quality control of feed water in power plants and in artesian-well water softening.  
AKMC-1 monitors consists of an electrochemical unit with ion-selective electrodes and a standard unit with a hydraulic unit. This design provides uninterrupted measurements of ion concentrations in real time with automatic correction for variations of temperature in the water flow.  
The instruments are equipped with RS-485 computer interfaces for customized report output and remote computer-aided control. Concentration measurement results, up to 1000, are stored in a built-in memory and are displayed on a built-in LCD or can be printed out. If the analysis result exceeds certain level, the alarm mode is activated, and a final-control mechanism can be automatically switched off by a command from the flow analyzer.



HOME | ABOUT COMPANY | PRODUCTS | APPLICATIONS | ANALYSIS TECHNIQUE | NEWS | CONTACT
 