| Online
training is available, call (330) 405-0837 for details. |
| Name |
 |
Brief
description of instruments |
| Mercury Analyzers |
 |
RA-915+
Mercury Analyzer

Optional attachments:
RP-91(for liquids)

RP-91C(for solid samples)
 |


 |
RA-915+
Mercury Analyzer is a portable spectrometer designed for
interference free analysis/monitoring of mercury content in ambient
air, water, soil, natural and stack gases, chlorine alkali manufacturing,
spill response, hazardous waste, foodstuff, biological materials.
US EPA validated high sensitivity and selectivity instrument that
does not require gold amalgam pre-concentration and subsequent regeneration
steps. This enables the user to conduct real time monitoring. Being
combined with an RP-91 Cold Vapor accessory for water and RP-91C
pyrolysis attachment for solid sample testing, the instrument is
designed to determine mercury content in ambient air, water, soil,
natural and stack gases, dental and medical testing and diagnostics,
analysis of food and fish, etc. The detection limits being as low
as 0.5 ng/m3 in air and 0.5 ng/l in water and 5 µg
in soil.
|
Mercury
Analyzer RA-915 Light
 |
 |
Mercury analyzer RA-915 LIGHT is a low cost analytical instrument for measuring mercury concentrations
in air. It is intended for assessment of indoor/outdoor air quality
in residential and industrial settings.
|
IRM-915
Transportable Mercury Stack Monitor
 |

|
IRM-915 Mercury Stack Monitor is developed for temporary
at-stack installation and Flue Gas testing for “Total” or “Elementary”
mercury. Designed as an instrumental replacement for Ontario Hydro
Method, this is a good tool for testing certification of permanent
CEMM’s, and on-site performance evaluation of Mercury Control Technologies.
IRM-915 Mercury Stack Monitor has recently
passed RATA (Relative Accuracy Test Audit). Result are available
per request. |
Appendix
K Sorbent Trap Mercury Analyzer

NEW! |
 
|
Appendix K part 75 of the Clean
Air Mercury Rule. US EPA validated thermal decomposition.
Appendix K Sorbent Trap Mercury Analyzer is designed for
field on-site or laboratory "Direct" testing of carbon
tubes for Sorbent Trap Monitoring of Hg emissions from coal-fired
power plants (formal method 324). Atomic Absorption technology is
used for no sample preparation analysis. Analysis time is less than
2 minutes per sample. No liquid chemicals or gases required, no
chemical waste is generated. In addition to Sorbent traps, analyzer
could be used for "Direct" testing of ash, coal and "Ontario
Hydro" method generated liquid samples.
Multi-point calibration protocol conforms to EPA Performance Based
Criteria Method.
Thermal method using RP M-324 Mercury Analyzer
and Sorbent Traps has passed RATA (Relative Accuracy Test Audit)
at multiple power plant locations in the United States. Result are
available per request. |
Appendix
K Sorbent Traps

NEW! |
 |
2 and 3-section Appendix K Sorbent Traps
are available in variety of sizes, both spiked and not spiked. Standard
concentrations and mercury speciation are available. |
RA-915
CEM
 |

|
Mercury CEM (Continuous Emission Monitor) is an industrial system for direct total mercury determination in stack gas with dry converter. Designed for outdoor installation on the stack, no heated lines needed.
|
RA-915
MiniCEM 1x
 |

|
RA-915 MiniCEM 1x
is designed for field on-site testing of Flue Gas for Total mercury.
Instrumental method intended as a replacement for Ontario Hydro
Method. This is a good tool for point source stack testing and
on-site performance evaluation of Mercury Control Technologies
Detection for Total mercury 0.5 µg/m3 - 200 µg/m3.
|
RA-915
MiniCEM 2x
 |

|
RA-915 MiniCEM 2x is designed for field on-site testing
of Flue Gas for Total mercury. Instrumental method intended as a
replacement for Ontario Hydro Method. This is a good tool for point
source stack testing and on-site performance evaluation of
Mercury Control Technologies Detection for Total mercury 0.1µg/m3
- 200 µg/m3.
|
RA-915+
Mercury Analyzer with new pyrolyzer PYRO-915
 |


 |
Direct mercury analyzer for
EPA Method 7473
is the unique high sensitivity interference-free instrument for
direct mercury determination in complex matrixes.
- No sample preparation involved.
- No compressed gases required.
- No chemical waste generated.
- Get accurate analytical results in less thàn a minute!
Method detection limit 0.5 ug/kg
|
MGA-915
 |


 |
MGA-915 Atomic Absorption
Spectrophotometer with electrothermal sample atomization and
enhanced Zeeman background correction features a compact benchtop
design, incorporating a fast 62.5-mm focal length monochromator
with a 1200-l/mm grating covering the 195-600-nm spectral range,
automatically controlled Massman graphite furnace, and automatically
interchangeable 6 hollow-cathode lamps or EDLs on a rotated turret.
It enables an analysis of more than 60 elements, primarily heavy
and toxic metals, to be carried out with very low detection limits
in such complex organic samples as milk, juices, wines, or blood
without preliminary sample digestion in a totally automated computer-aided
operation mode, including automated adjustment for the given element.
The spectrophotometer is equipped with a 100-position autosampler. |
Mercury
Analyzer RA-82
 |
 |
Mercury Analyzer RA-82
is employed for measuring weight concentration of mercury, which
is implemented using a double-beam optical scheme with analytical
and reference cells. To minimize the detection limit, mercury preconcentration
on a gold trap is used. |
| Mercury Filters |
 |
Mercury
Vapor Filter Scrubber
 |
 |
Mercury Vapor Filter Scrubber is designed for cleaning air from
vapors of elementary mercury in breezing zone, for spill clean up,
dental offices, manufacturing facilities, room decontamination,
medical offices, schools, etc.
* 3 models available
|
 |
| IR Spectrometry |
 |
InfraLUM
FT-02
 |


 |
InfraLUM FT-02 FTIR Spectrometer
contains, as a basic unit, a state-of-the-art robust vibration-
and misalignment-proof Double-Cat-Eye interferometer of a proprietary
design. The InfraLum-02 covers the spectral range of 350-7500
cm-1 and provides the photometric accuracy of 0.1%. The
instrument is designed for identification of unknown substances,
quantitative analysis of solutions and mixes, detection of impurities
in atmospheric air and gases, and other similar analyses. The large
sample compartment can accommodate all conventional and non-standard
large cells and accessories. The use of the dedicated user-friendly
SpectraLum control, data acquisition and processing software package,
and calibration and reference databases allows even an unskilled
operator to operate the instrument. |
InfraLUM
FT-10
 |


 |
InfraLUM FT-10 FT-NIR Analyzer
is a multipurpose near-IR (8500-14 500 cm-1 ) FT spectrometer,
which is designed for laboratory analysis of basic components of
food products, grains, and feed mixes, such as proteins, fats, moisture,
sugar, cellulose, starch, fibers, salt, etc., Determination of such
biological properties of a sample as the sprouting ability of seeds,
caloric content of food products, grain size, and others can be
also achieved using this machine. The instrument employs the NIR-transmission
technique, accommodates most of chemometrics prediction algorithms,
and allows for high flexibility of analysis methods. The analyzer
is controlled by a dedicated SpectraLUM/Pro software, which enables
to carry out routine analyses in a very simple dialogue mode, so
that even an unskilled operator can operate the instrument. |
 |
| Capillary electrophoresis |
 |
CAPEL-series
 |


|
CAPEL-series Capillary Electrophoresis
Systems. Capel-103 and its upgraded versions Capel-104 and ?05
are high-performance CE instruments equipped with light sources
and photometric detectors. Models 103 and 104 operate at a 254-nm
wavelength, while Capel-105 is equipped with a detector and UV monochromator,
covering the 190-380-nm spectral range. Capel-103 has a manualy
controlled sampler with 4 inlet and 2 outlet positions, and Capel-104
and ?05 have autosamplers with 10 inlet and 10 outlet positions.
The samples, rinsing and buffer solutions are injected automatically
by pressure or electrokinetically according to a preset program.
All the instruments are equipped with capillary cassettes, containing
air (103)- or liquid-cooled capillaries of 30-100-cm in length and
25-100 µm i.d., reversible polarity ?5 kV voltage supply units,
and with customized report outputs (hard copy and file). The dedicated
software package supports data acquisition and processing, data
exchanges with worksheets, databases and word processors. The software
package utilizes a standard PC and powerful Chrom&Spec software
package, which makes the analysis fully automated.
|
 |
| Luminescent and absorption
photometric analysis |
 |
Fluorat-02-series
 |


 |
Fluorat-02-series Analyzers
employ the modular principle to diversify the highly sensitive and
selective luminescent analysis technique. The base unit, Fluorat-02,
is a filter-based fluorometer, photometer, and chemoluminometer.
All these modes of operation are implemented in the same optoelectronic
scheme. In addition, the Fluorat-02-2M version is a time-resolving
fluorometer, which can be used as a fluorometric detector in any
HPLC system. The analyzers are equipped with high-pressure xenon
arc lamps, with a high-intensity light in the 200-650-nm spectral
range, and are furnished with appropriate sets of light filters
and measuring cells. Fluorat-02-02/3M analyzers operate in
a user-friendly menu mode to analyze common contaminants, such as
petroleum hydrocarbons, phenols, surfactants, formaldehyde, nitrites,
nitrates, sulfides, fluorides, and a number of elements. The software
package allows for saving calibration tables and background value
for 16 different components in the built-in memory, and for printing
out the results of analysis. These analyzers can also operate with
a fiber optic cable to measure luminescence or reflected light from
the surface of an outside sample, such as paper, cathodoluminophors,
etc. The small (300x300x90 mm) and light-weight (8 kg) analyzers
are energized from an ac mains or from a 12-V battery, which allows
their use in mobile laboratories. |
CRYO-1
and -2
 |


|
CRYO-1 and -2 Cryogenic
Systems are designed for cryospectroluminescent analyses of
benz(a)pyrene in various objects and of lead in samples of potable,
natural and waste water, and in food products (in addition, Bi,
Te, and Se can also be detected). The system constains a Fluorat-02-2M
analyzer and a cryogenic unit (plus an LM-3 monochromator in Cryo-1),
which are connected via fiber optic bundles. The cryogenic unit,
where a substance under study is cooled to 77K using liquid nitrogen,
consists of a rack, Dewar vessel, and a device for the uniform feed
of samples being measured. |
Fluorat-02-Panorama
Spectrofluorometer
 |


 |
Fluorat-02-Panorama Spectrofluorometer
incorporates two monochromators in the luminescence excitation
and detection paths, which are arranged in a compact two-level configuration,
a xenon flashlamp as a light source, and a PMT as a detector of
luminescence signals. The monochromators employ 900-l/mm concave
diffraction gratings with a 100-mm radius of curvature, covering
the 210-730-nm spectral range. The wavelengths are set either from
a built-in keypad or using a computer control program. The instrument
is designed for analysis of luminescence spectra of liquid and solid
samples, chromatographic analysis of several components during a
single eluation, and is capable of scanning synchronous or two-dimensional
spectra in both excitation and luminescence detection paths. |
 |
| High Performance Liquid
Chromatography (HPLC) |
 |
HPLC
system
 |


 |
HPLC system consists
of a Fluorat-02-2M analyzer, used as a detector, and a Python pump.
The Fluorat-02-2M analyzer is designed for the detection of mycotoxins,
hormones, nitroso amines, histamine and other biogenic amines, benz(a)pyrene,
vitamins, and other compounds. The analyzer is equipped with an
RS-232 interface, which allows recording chromatograms in real time.
A built-in microprocessor provides signal processing and a customized
report of the results of the analysis. It makes the output signals
compatible with the PC Chrom&Spec® software dedicated to
chromatographic data processing. The Python syringe-type pump provides
a precise and predictable pulsation-free eluent flow and pressure.
It is specifically designed to handle aqueous, organic, corrosive,
and viscous liquids. The pump has a multifunctional control unit
with a built-in keypad, which simplifies routine operations. An
eluent gradient can be created by the action of two pumps operating
together. |
Fluorat-02-Panorama
detector
 |


 |
To carry out very complicated
analyses, for example, to analyze polyaromatic hydrocarbons, it
is convenient to use a spectrofluorometric FLUORAT?/sup>-02-PANORAMA
analyzer. This instrument enables program-controlled adjustment
of both monochromators as a function of the elution time. In this
fashion, several compounds, for example, 15 specified polyaromatic
hydrocarbons, can be detected with the highest sensitivity. |
 |
| Automatic Analyzers |
 |
Fluorat
A-series
 |


 |
Fluorat A-series Automatic
Flow Extraction Analyzers are intended for stand-alone unattended
continuous monitoring of the content of petroleum hydrocarbons (0.005-5
mg/l), aluminum (0.005-5 mg/l), active chlorine (0.03-3 mg/l), ozone
(0.01-5 mg/l), and surfactants (0.05-5 mg/l) in potable, natural,
and waste water or for assaying a series of samples using the fluorescence
technique. The instruments comprise a luminescence detector and
a sample preparation unit, which provides metered feed and switching
of the water and gas flows, and control of temperature, mixing,
and mass-exchange processes. In a stand-alone operating mode, the
selected reaction sequence can be assigned from a built-in keyboard
and allows wide-range altering the flow rates from 0.02 to 20 l/min.
The instruments are equipped with RS-232 computer interfaces for
customized report output and remote computer-aided control. Concentration
measurement results, up to 1000, are stored in a built-in memory
and are displayed on a built-in LCD or printed out. If the analysis
result exceeds a permissible level, the alarm mode is activated,
and a final-control mechanism can be automatically switched off
by a command from the flow analyzer. |
CKAT
 |


 |
CKAT-1 on-line turbidimeter
monitor is intended for stand-alone unattended continuous monitoring
in ecological, technological and sanitary purposes.
Principle of operation of this device is based on the effect of
light scattering by suspended particles and emulsions.
The instruments comprise a source of light, a water flowing cell
and a matrix of photodetectors and allow to detect a turbidity in
any natural and industrial water flows. The instruments are equipped
with RS-485 computer interfaces for customized report output and
remote computer-aided control. Concentration measurement results,
up to 1000, are stored in a built-in memory and are displayed on
a built-in LCD or printed out. If the analysis result exceeds a
permissible level, the alarm mode is activated, and a final-control
mechanism can be automatically switched off by a command from the
flow analyzer. |
AKMC
 |


 |
AKMC-1 water hardness
monitor is designed for stand-alone unattended continuous monitoring.
The principle of operation of this instrument is based on potentiometric
determination of the total content of calcium and magnesium ions
(water hardness) in any natural or industrial water samples. The
device may be used for monitoring at water preparation facilities
and for quality control of feed water in power plants and in artesian-well
water softening. AKMC-1 monitors consists of an
electrochemical unit with ion-selective electrodes and a standard
unit with a hydraulic unit. This design provides uninterrupted measurements
of ion concentrations in real time with automatic correction for
variations of temperature in the water flow.
The instruments are equipped with RS-485 computer interfaces for
customized report output and remote computer-aided control. Concentration
measurement results, up to 1000, are stored in a built-in memory
and are displayed on a built-in LCD or can be printed out. If the
analysis result exceeds certain level, the alarm mode is activated,
and a final-control mechanism can be automatically switched off
by a command from the flow analyzer. |
 |
| Microwave sample digestion |
 |
Minotavr
 |


 |
Minotavr Microwave Sample Digestor
provides automated full preparation of any samples for an elemental
analysis by the AAS, luminescence, or photometric technique. A sample
of such an organic substance as meat, fish, grains, bread, vegetables
and fruits, potable or waste water, soft drinks and alcoholic beverages,
tea and coffee, etc., is digested by a controlled 2450-MHz and 40-400-W
microwave field in a closed vessel under pressure up to 8 atm, which
ensures fast complete, and reproducible digestion, preventing the
sample from a loss of readily volatile elements and reducing the
consumption of reagents. Normally, a 2-g solid or 50-ml liquid sample
is completely decomposed in 15 to 30 min. |
 |
| Monochromators |
 |
Monochromators
 |

 |
Monochromators line comprises MCD-2
double monochromators and LM-3 monochromators, which are intended
for the use with analytical instruments operating in the UV-VIS
(respectively, 280-710 nm and 200-750 nm) spectral range. The MCD-2,
which feature an extremely high signal-to-noise light ratio of 3x106,
are made by a proprietary design concept based on two concave 1250-l/mm
diffraction gratings with a special groove profile and two deflecting
plane mirrors, which provides an F-number of 1:4 and a high resolution
of 0.33 nm throughout the working spectral range. The LM-3 have
one concave diffraction grating with a special groove profile, the
F-number being 1:3.3 and resolution 1.2-1.4 nm. In both monochromators,
slits are formed in easily removable fiber optical lug from 200-µm
diameter quartz cores packed in rows. |
 |
| Accessories |
 |
Lamps
for atomic absorption
 |
 |
A great variety
of hollow-cathode and electrodeless lamps for nearly all of the
elements of periodic table and graphite furnace tubes for AAS analyses;
glass and quartz cells of various sizes for luminescent and photometric
analyses; accessories for IR spectroscopy, such as a two-column
10-ton laboratory press, IR crystalline KBr, NaCl, and CsI windows,
macro-micro KBr die, grinder/mixer, demountable gas and liquid cells,
and sealed pathlength cells. |
Graphite
Furnace
 |
 |
|
 |
|
 |
|
|

|