  Method 30B Unspiked Sorbent Traps for "Total" Mercury Testing

 

Method 30B Sorbent Traps are available for evaluations and RATA. These 6mm or 10mm extra durable 2-section sorbent traps are typically used from a few hours to one day sampling and can be used when pulling up to 2 liters per minute flow.

Method 30B is a procedure for measuring total vapor phase mercury (Hg) emissions from coal-fired combustion sources using sorbent trap sampling and an extractive or thermal analytical technique.

Method 30B Testing Traps and portable Direct Sorbent Trap analyzer are available from Ohio Lumex to satisfy strict QA/QC procedures outlined in the method.

Ohio Lumex Method 30B Unspiked Sorbent Trap


Method 30B Sorbent Traps Technical Specifications
  • Spiked/Un-Spiked 2-section Sorbent Traps availabe in 10 mm OD;
  • Iodinated, acid washed coconut shell charcoal. 300 mg on each trap section. Carefully sized to fit the Sorbent Trap Analyzer precisely allowing each bed to be analyzed with its plug cutting analysis time in half;
  • Low mercury background levels - less than 1 ng per section;
  • Low Mass Emitter Traps available with less than 0.2 ng per section;
  • Larger internal diameter drops gas velocity inside of the trap causing less pluggage and enables a higher flow rate of up to 2 liters per minute without experiencing pressure drop. Higher flow rate places the operator in control of mercury mass loading;
  • Low Mass Emitter Traps have been specially made to allow up to 4 liters per minute;
  • Easy to remove and easy to set for “leak check” cap plugs; color coded;
  • Unique sample high temperature ID ink with chain of custody sheet in protective pack;
  • Size “Calibrated” extra thick glass for trap rigidity;
  • Customized Spiking level - from 10 ng to 200,000 ng loading available;
  • 10% of every spiked traps batch analyzed and recorded for QA/QC purpose;
  • Rigorous QA/QC procedures at every manufacturing step;
  • Long term storage stability - 1year; no special storage required;
  • Available immediately from stock with or without analysis;
  • Significant discounts on large quantities - contract based orders;
  • Can be used in wet and dry stacks;
  • In-house analysis with same, 24 hour, or short turnaround time.

 

 